Ketta TopGun aluminium calf milk nozzle and CR120 digital flow meter
Swivel inlet port
25 mm (1 inch) hose tail and loose nut
Hose clip included
Condor CR120 digital flow meter
For water, calf milk, AdBlue and more
5 to 100 lpm (1.3 to 26.4 gpm)
10 bar (145 psi)
Ketta CR120 flow meter features:
• reinforced polyamide (plastic) body
• polypropylene turbine
• impulse-type signals with a single channel, reed switch
• 5 digit batch display from 0.1 to 99,999 litres
• 6 digit total display from 1 to 999,999 litres
• re-settable total
• flow rate indication
• +/- 1% accuracy
• loss of pressure < 0.03 bar at 120 lpm
• can be calibrated
• powered by two AAA batteries (batteries are included)
Applications include:
Water
Animal food
Milk for calves
Windscreen washer fluid
Antifreeze
Some other aggressive type fluids
Applications include:
Water
Animal food
AdBlue
DEF
SuzzaraBlue
Urea
Milk for calves
Windscreen washer fluid
Antifreeze
Some other aggressive type fluids
Trouble shooting the Condor CR120 flow meter:
Problem: CR120 digital display is not reading or is not reading correctly
1. replace the batteries:
To change the batteries proceed as follows:
• press RESET to update all the totals
• loosen the 4 fixing screws of the back cover
• remove the old batteries
• place the new batteries in the same position as the old ones
• close the cover again, by positioning the rubber protection as a gasket
• CR120 will switch on automatically and normal operation can be resumed
The CR120 will display the same Reset Total, the same Total and the same Partial indicated before the batteries were changed
After changing the batteries, the meter does not need calibrating again
2. check to see if the turbine is spinning freely
To remove the turbine for cleaning:
• spring clips are located either side of the turbine
• these can be removed with a small nail file etc
• ensure meter body and turbine is completely clean and free of debris
3. check to see if electronic system is free of moisture and completely dry
• remove 4 x screws from display face to access electronic system
4. display still does not function correctly?
CR120 flow meter will need to be replaced